Charge Pump

Run Characteristics

Solver  Rtol  Atol  H0  Scd  Mescd  Steps  Accept  f-eval  J-eval  LU-dec  CPU-time
BIMD 1.0E-02 1.0E-02 1.0E-08 -1.18 1.85 429 299 4381 299 429 2.49E-02
1.0E-04 1.0E-04 1.0E-10 -1.19 2.63 539 389 5551 389 539 3.14E-02
1.0E-06 1.0E-06 1.0E-12 4.66 8.47 1005 679 13639 679 1005 7.55E-02
DASSL 1.0E-02 1.0E-02   failed run
1.0E-04 1.0E-04   1.73 5.55 1270 1060 2106 1030   2.83E-02
1.0E-06 1.0E-06   2.42 6.23 2264 1824 3720 1684   4.86E-02
GAMD 1.0E-02 1.0E-02 1.0E-08 -0.98 2.50 370 240 4470 240 370 2.04E-02
1.0E-04 1.0E-04 1.0E-10 -0.71 3.10 730 470 12094 460 720 5.03E-02
1.0E-06 1.0E-06 1.0E-12 0.35 4.17 878 596 21278 533 789 8.17E-02
MEBDFDAE 1.0E-02 1.0E-02 1.0E-08 failed run
1.0E-04 1.0E-04 1.0E-10 failed run
1.0E-06 1.0E-06 1.0E-12 failed run
MEBDFI 1.0E-02 1.0E-02 1.0E-08 -0.13 2.29 1110 927 6973 327 327 2.25E-02
1.0E-04 1.0E-04 1.0E-10 0.25 4.03 2628 2111 18179 912 912 5.55E-02
1.0E-06 1.0E-06 1.0E-12 0.33 4.14 4299 3505 29859 1502 1502 9.15E-02
RADAU 1.0E-02 1.0E-02 1.0E-08 failed run
1.0E-04 1.0E-04 1.0E-10 failed run
1.0E-06 1.0E-06 1.0E-12 failed run
RADAU5 1.0E-02 1.0E-02 1.0E-08 failed run
1.0E-04 1.0E-04 1.0E-10 failed run
1.0E-06 1.0E-06 1.0E-12 failed run


Work-Precision Diagrams

ChartObject Chart 1

ChartObject Chart 5

Parameters used for the construction of the WPD:

RTOL(J) = TOL,    J = 1,...,8;     ATOL(J) = 10-6TOL,    J = 1,...,5;       ATOL(J) = TOL,   J = 6,...,8,

ATOL(9) = RTOL(9) = 1000   for   DASSL;     ATOL(9) = RTOL(9) = TOL,    for other solvers;

H0=10-6TOL    

where TOL = 10-(1+M/2),    M = 0,...,12.



REMARK: for the computation of the number of significant correct digits (scd) all the components are taken into account.